BN Part Number 172036 Revision NC, May 2005
Page 1 of 13
元器件交易网www.cecb2b.com
3300 5mm Probes and XL Extension Cables can be ordered with connector protectors already installed, or the connector protectors supplied separately for installation in the field (such as when the cable must be run through restrictive conduit). Connector protectors are recommended for all
installations and provide increased environmental protection7.
Notes:
1. A 5 mm probe uses smaller physical packaging while providing the
same linear range as a 3300 XL 8 mm probe (ref 141194-01);
however, it does not permit reduced sideview clearances or tip-to-tip spacing requirements compared to an XL 8 mm probe. It is used when physical (not electrical) constraints preclude the use of an 8 mm probe, such as mounting between thrust bearing pads or other constrained spaces. When narrow sideview probes are required, use the 3300 XL NSv™ probe and extension cable with the 3300 XL NSv Proximitor® Sensor (refer to Specifications and Ordering Information p/n 147385-01).
2. XL 8 mm probes provide a thicker encapsulation of the probe coil in
the molded PPS plastic probe tip. This results in a more rugged probe. The larger diameter of the probe body also provides a stronger, more robust case. Bently Nevada recommends the use of XL 8 mm probes when possible to provide optimal robustness against physical abuse. 3. A 3300 XL Proximitor® Sensor is available and provides many
improvements over the non-XL version. It is electrically and
mechanically interchangeable with the non-XL version. Although the packaging of the 3300 XL Proximitor® Sensor differs from its predecessor, its design allows it to fit in the same 4-hole mounting pattern when used with the 4-hole mounting base, and to fit within the same mounting space specifications (when minimum permissible cable bend radius is observed). Consult Specifications and Ordering
Information (p/n 141194-01) or our Bently Nevada Sales and Service Professional for more information.
4. Us of XL components with 3300 5mm Probes will limit system
performance to the specifications for the non-XL 3300 system.
5. The factory supplies Proximitor® Sensors calibrated by default to AISI
4140 steel. Calibration to other target materials is available upon request.
6. When considering this transducer system for tachometer or over speed
measurements, consult www.bently.com for the application note regarding the use of eddy current proximity probes for over speed protection.
7. Silicone tape is also provided with each 3300 XL extension cable and
can be used instead of connector protectors. Silicone tape is not recommended in applications where the probe-to-extension cable connection will be exposed to turbine oil.
Specifications
Unless otherwise noted, the following specifications are for a proximity transducer system between +18° C and +27° C (+64° F to +80° F) with a -24 Vdc power supply, a 10 kΩ load, an AISI 4140 steel target, and a probe gapped at 1.27 mm (50 mils).
Electrical
BN Part Number 172036 Revision NC, May 2005
XL Proximitor® Accepts one noncontacting 3300 Sensor Input: 5 mm Proximity Probe and XL Extension Cable.
Power:
Requires -17.5 Vdc to -26 Vdc at 12 mA maximum consumption. Operation at a more positive voltage than -23.5 Vdc can result in reduced linear range.
Supply Sensitivity:
Less than 2 mV change in output voltage per volt change in input voltage. Output resistance: 50 Ω
Probe dc resistance (R PROBE)
Probe Length (m) Resistance from the Center Conductor
to the Outer Conductor (Ω)
0.5 7.45 ± 0.50 1.0 7.59 ± 0.50 1.5 7.73 ± 0.50 2.0 7.88 ± 0.50 5.0 8.73 ± 0.70 9.0 9.87 ± 0.90
Extension cable dc resistance
Length of
Resistance from Resistance from Extension Center Conductor to
Outer Conductor to Cable
Center Conductor Outer Conductor (RCORE) (Ω) (RJACKET) (Ω)
3.0 0.66 ± 0.10 0.20 ± 0.04 3.5 0.77 ± 0.12 0.23 ± 0.05 4.0 0.88 ± 0.13 0.26 ± 0.05 4.5 0.99 ± 0.15 0.30 ± 0.06 7.0 1.54 ± 0.23 0.46 ± 0.09 7.5 1.65 ± 0.25 0.49 ± 0.10 8.0 1.76 ± 0.26 0.53 ± 0.11 8.5 1.87 ± 0.28 0.56 ± 0.11
Note: Outer conductor refers to the shielded conductor that is attached to the connector, not the armor braid.
Extension cable 69.9 pF/m (21.3 pF/ft) typical. capacitance:
Field Wiring:
Recommend using three-conductor shielded triad cable 0.2mm to 1.5mm (16 AWG to 24 AWG). 305 metres (1,000 feet) maximum length between 3300 XL Proximity
Transducer and monitor. Consult Performance Specification 155687 for signal rolloff at high frequencies
Page 2 of 13
元器件交易网www.cecb2b.com
Linear Range: Recommended Gap Setting: Incremental Scale Factor: Deviation from best fit straight line (DSL): Probe Temperature Stability (typical): Frequency Response: Minimum Target Size: Shaft Diameter
Minimum: Recommended minimum: BNC Part Number 172036 Revision NC, May 2005
when using longer field wiring lengths or external safety barriers located some distance from the monitoring system.
2 mm (80 mils). Linear range begins
at approximately 0.25 mm (10 mils) from target and is from 0.25 to 2.3 mm (10 to 90 mils).
1.27 mm (50 mils).
7.87 V/mm (200 mV/mil) ±6.5% typical, including interchangeability
error when measured in increments of 0.25 mm (10 mils) over the linear range.
Less than ±0.038 mm (±1.5 mil) typical deviation from best fit straight
line.
Over probe temperature range of -35° C to +177° C (-31° F to +350°
F), the incremental scale factor remains within ±10% of 7.87 V/mm (200 mV/mil) and the deviation from the best fit straight line remains within ±0.076 mm (±3 mils).
0 to 10 kHz: +0, -3 dB, with up to 305 metres (1000 feet) of field
wiring.
15.2 mm (0.6 in) diameter
(flat target).
50.8 mm (2 in)
76.2 mm (3 in)
When gapped at the center of the linear range, the interaction between two separate transducer systems (cross-talk) will be less than 50 mV on shaft diameters of at least 50 mm (2 in) or greater. Care should be taken to maintain minimum separation of transducer tips, generally at least 40 mm (1.6 in) for axial position measurements or 38 mm (1.5 in) for radial vibration measurements to limit cross-talk to 50 mV or less. Radial vibration or position measurements on shaft diameters smaller than 76.2 mm (3 in) will generally result in a change in scale factor. Consult Performance Specification 155687 for additional information.
Effects of 60 Hz Magnetic Fields Up to 300 Gauss
(5 metre system):
Output voltage in mil pp/gauss:
Gap XL Probe XL Ext.
Proximitor® Cable Sensor
10 mil 0.0119 0.0004 0.0004 50 mil 0.0131 0.0014 0.0014 90 mil 0.0133 0.0045 0.0045
Electrical Complies with the European CE Certification: mark.
Multiple approvals for hazardous Hazardous Area
areas certified by Canadian Approvals
Standards Association (CSA/NRTL/C) in North America and by Baseefa (2001) in Europe.
North America: Ex ia IIC T4/T5 for Class I Zone 0 or
Class 1 Division 1; Groups A, B, C, and D, when installed with
intrinsically safe zener barriers per drawing 141092, or when installed with galvanic isolators.
Ex nA IIC T4/T5 for Class I Zone 2 or Class 1 Division 2, Groups A, B, C, and D when installed without barriers per drawing 140979
T5 @ Ta = -35° C to 85° C. T4 @ Ta = -51° C to +100° C
Europe: II 1 G EEx ia IIC T4/T5 EC certificate numberBAS99ATEX1101, when installed per per drawing 141092.
II 3 G EEx nA II T4/T5. EC certificate number
BAS99ATEX3100U, when installed
per drawing 140979.
Page 3 of 13
元器件交易网www.cecb2b.com
T5 @ Ta = -35° C to 85° C. T4 @ Ta = -51° C to +100° C
IEC Ex:
3300 XL Proximitor® Sensor, ia
IECEx BAS04.0055X Ex ia IIC T4 / T5 (-51ºC = Ta = +100ºC / -35ºC = Ta = +85ºC) Terminal Block Connections Ui= -28V Ci = 0 Ii= 140mA Li =10µH
Pi= 0.84W Coaxial Connection Ui = -28V Ci= 5.7nF Ii = 140mA Li = 0.85mH Pi = 0.84W Load Parameters
The capacitance and either the inductance or the inductance to resistance (L/R) ratio of the load connected to the probe coaxial terminal, must not exceed the following values:
3300 XL Proximitor® Sensor, nA
IECEx BAS04.0057X
Ex nA II T4 / T5 (-51º C = Ta = +100º C / -35º C = Ta = +85º C) The terminals must be provided with a level of protection of at least IP54. Ui = -28V
3300 5mm Eddy Current Probe, ia
IECEx BAS04.0056
BNC Part Number 172036 Revision NC, May 2005
Ex ia IIC Temperature Classification per below.
T1: -51º C to +232º C T2: -51º C to +177º C T3: -51º C to +120º C T4: -51º C to +80º C T5: -51º C to +40º C
Ui = -28V Ci = 1.5nF Ii = 140mA Li = 200µH
Pi =0.84W
3300 5mm Eddy Current Probe, nA IECEx BAS04.0058X Ex nA II Temperature Classification per the
temperature classifications above.
Must be supplied from a voltage limited source.
EEx nA for Zone 2, Group IIC, EC certificate number BAS99ATEX3100U.
Mechanical
Probe Tip Material: Polyphenylene sulfide (PPS).
Probe Case Material: AISI 303 or 304 stainless steel (SST).
Probe Cable:
75 Ohm triaxial, fluoroethylene propylene (FEP) insulated probe cable in the following lengths: 0.5, 1, 2, 5, or 9 metres.
System Length: 5 or 9 metres including extension cable.
Extension Cable Material 75 Ω triaxial, fluoroethylene propylene (FEP) insulated.
Probe and Extension
Flexible AISI 302 or 304 SST with Cable Armor FEP outer jacket
Page 4 of 13
元器件交易网www.cecb2b.com
Tensile Strength
5 mm probe: 222 N (50 lbf) probe case to probe lead. 222 N (50 lbf) probe lead to extension cable connectors.
Connector material: Gold-plated brass or gold-plated beryllium copper.
Probe case torque:
Recommended torque: 2.8 N·m (25 in·lb) Maximum torque: 8.5 N·m (75 in·lb)
Connector-to-connector torque
Recommended See table below. torque:
Maximum torque: 0.565 N•m (5 in•ft)
Connector Type Tightening Instructions
Two 3300 XL gold \"click\"
Finger tight type connectors One non-XL stainless steel
Finger tight plus 1/8 turn
connector and one using pliers
3300 XL connector
Minimum Cable Bend 25.4 mm (1.0 in). Radius:
Total System Weight: 0.71 kg (1.6 lbm), typical.
3300 5mm Probe: 323 g (11.39 oz). XL Extension
Cable: 34 g/m (0.4 oz/ft)
103 g/m (1.5 oz/ft) (armored)
XL Proximitor® 246 g (8.7 oz)
Sensor:
Environmental Limits
Probe Temperature Range: -35° C to +177° C (-31° F to +351°
F)
BNC Part Number 172036 Revision NC, May 2005
Note: Exposing the probe to temperatures below -34°C (-30°F) may cause premature failure of the pressure seal.
Extension Cable Temperature Range:
-51° C to +177° C (-60° F to +351° F) for standard extension cable. ref 141194-01
Probe Pressure:
3300 5 mm probes are designed to seal differential pressure between the probe tip and case. The probe sealing material consists of a fluorocarbon O-ring. Probes are not pressure tested prior to shipment. Contact our custom design department if you require a test of the pressure seal for your application.
Note: It is the responsibility of the
customer or user to ensure that all liquids and gases are contained and safely controlled should leakage occur from a proximity probe. In addition, solutions with high or low pH values may erode the tip assembly of the probe causing media leakage into surrounding areas. Bently Nevada®, LLC will not be held responsible for any damages resulting from leaking 3300 5 mm proximity probes. In addition, 3300 5 mm proximity probes will not be replaced under the service plan due to probe leakage.
Patents:
Components or procedures
5,016,343; 5,126,664; described in these patents apply to 5,351,388; and this product 5,685,884.
Ordering Information
Page 5 of 13
元器件交易网www.cecb2b.com
3300 5 mm Proximity Probes
330171 3300 5 mm Probe, 1/4-28 UNF thread, without armor
330172 3300 5 mm Probe, 1/4-28 UNF thread, with armor
Part Number-AXX-BXX-CXX-DXX-EXX Option Descriptions
A: Unthreaded
Note: Unthreaded length must be at least Length Option
0.8 in less than the case length.
Order in increments of 0.1in Length configurations:
Maximum unthreaded length: 8.8 in = 8 8.
Minimum unthreaded length: 0.0 in = 0 0.
Example: 0 4 = 0.4 in
B: Overall Case Order in increments of 0.1 in Length Option Threaded length configurations:
Maximum case length: 9.6 in = 9 6. Minimum case length: 0.8 in = 0 8. Example: 2 4 = 2.4 in
C: Total Length 0 5 0.5 metre (1.6 feet) Option 1 0 1.0 metre (3.3 feet)
2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet) 1 9 0 9.0 metres (29.5 feet)
D: Connector Option 0 1 Miniature coaxial ClickLoc™
connector with connector protector, standard cable 0 2 Miniature coaxial ClickLoc™
connector, standard cable
E: Agency Approval 0 0 Not required Option 0 5 Multiple Approvals
3300 5 mm Proximity Probes, Metric
330173 3300 5 mm Probe, M8 x 1 thread, without armor 330174 3300 5 mm Probe, M8 x 1 thread, with armor
Part Number-AXX-BXX-CXX-DXX-EXX Option Descriptions
BNC Part Number 172036
Revision NC, May 2005
A: Unthreaded Note: Unthreaded length must be at least Length Option
20 mm less than the case length.
Order in increments of 10 mm. Length configuration:
Maximum unthreaded length: 230 mm = 2 3.
Minimum unthreaded length: 0.0 mm = 0 0.
Example: 0 6 = 60 mm.
B: Overall Case Order in increments of 10 mm. Length Option
Metric thread configurations: Maximum length: 250 mm = 2 5. Minimum length: 20 mm = 0 2. Examples: 0 6 = 60 mm.
C: Total Length 0 5 0.5 metre (1.6 feet) Option
1 0 1.0 metre (3.3 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet) 1 9 0 9.0 metres (29.5 feet)
D: Connector Option
0 0 No connector supplied,
standard cable
0 1 Miniature coaxial ClickLoc™
connector with connector protector, standard cable 0 2 Miniature coaxial ClickLoc™
connector, standard cable
E: Agency Approval 0 0 Not required
Option
0 5 Multiple Approvals
3300 XL Proximitor® Sensor
See 141194-01. Make sure that the extension cable
length and the probe length, when added together, equal the Proximitor® Sensor total length. 3300 XL Extension Cable
See 141194-01Make sure that the extension cable length and the probe length, when added together, equal the Proximitor® Sensor total length.
Page 6 of 13
元器件交易网www.cecb2b.com
Accessories
141078-01 Manual
02120015 Bulk field wire. 1.0 mm2 (18 AWG),
3-conductor, twisted, shielded cable for connections between
Proximitor® Sensor and monitor.
Aluminum probe mounting bracket 137492 -AXX
Option Descriptions
A: Thread size
0 2 1/4-28 0 3 M8 x 1
The aluminum probe threaded mounting bracket is the standard mounting bracket for most 3300 5 mm probe installations. The -02 option is supplied with two 10-24 UNC-2A mounting screws. The -03 option is supplied with two M5 x 0.8-6g mounting screws. The mounting screws have pre-drilled holes for safety wire.
Phenolic probe mounting bracket 27474 -AXX
Option Descriptions
A: Thread size 0 2 1/4-28
0 3 M8 x 1
The phenolic mounting bracket is recommended if additional electric isolation from the mounting location is required (as in some generator and electrical motor bearing locations). The -02 option is supplied with two 10-24 UNC-2A mounting screws. The -03 option is supplied with two M5 x 0.8-6g mounting screws. The mounting screws have pre-drilled holes for safety wire.
BNC Part Number 172036 Revision NC, May 2005
03200006
Silicone self-fusing tape
40113-03 Connector Protector Kit 136536-01 Connector Protector Adapter 40180-03 Connector Protectors 03839410
75 ohm Triaxial/95
ohm Coaxial Male
Connector Protector
03800001
75 ohm Coaxial
Female Connector Protector 163356 Connector Crimp Tool Kit 75 Ω ClickLoc™
Connector Kit
330153-AA
Option Descriptions
9.1 metre (10 yard) roll of silicone tape to protect connectors. It is easy to install and provides excellent electrical isolation and protection from the environment. It is not recommended for use inside the casing of the machine.
Connector Protector Kit for 3300 5 mm probes, including connector protectors and installation tools.
Makes connector protector kits purchased prior to 1998 compatible with ClickLoc™ extension cable
connectors.
Package containing 10 pairs of 75 ohm Coaxial Connector Protectors.
Placed onto the extension cable; attaches to the female connector protector on the 5 mm probe to provide environmental protection of
connectors.
Placed onto 3300 5 mm probe leads; attaches to the male connector protector on the extension cable to provide environmental
protection of connectors.
Includes one set of multi-connector inserts and connector installation instructions. Compatible only with 330153 connector kits or with probes shipped in 2003 or later with ClickLoc™ connectors uninstalled. Supplied with carrying case.
0 2 One ClickLoc™ male connector for 3300 XL 5 mm and 8 mm extension cable.
0 3 One ClickLoc™ female
connector for 3300 XL 5 mm and 8 mm extension cable.
Page 7 of 13
元器件交易网www.cecb2b.com
0 4 One ClickLoc™ male connector for 3300 5 mm probe.
75 Ω ClickLoc™ Connector Kit for 3300 series probes and extension cables. Each kit contains one color-coded sleeve per connector.
© 2005 Bently Nevada®, LLC
CableLoc™, ClickLoc™, FluidLoc®, Keyphasor®, NSv™, Proximitor®, and TipLoc™ are trademarks of Bently Nevada, LLC.
Viton® is a registered trademark of DuPont Dow Elastomers L.L.C.
BNC Part Number 172036 Revision NC, May 2005
Page 8 of 13
元器件交易网www.cecb2b.com
Graphs
Figure 1 - Typical 3300 5 mm probe and 1 metre of cable at high and low temperatures (XL
Proximitor® Sensor and XL extension cable are at 25°C)
BNC Part Number 172036 Revision NC, May 2005
Page 9 of 13
元器件交易网www.cecb2b.com
Figure 2 - 3300 5 metre XL Proximitor® Sensor at high temperatures (3300 5mm probe and XL extension cable at 25° C)
BNC Part Number 172036 Revision NC, May 2005
Page 10 of 13
元器件交易网www.cecb2b.com
Dimensional diagrams
5.6 (7/32) Wrench Flats for 1/4-28 threads,7.0 (0.28) for M8 threads, 4 each11.1(7/16) for 1/4-28 threads313.0 (0.51) for M8 threads35.2Dia.(0.21)CaseThreadProbe Tip75 ohm Cable2.8 (0.11) Max Outside Dia.7.6 (0.30) Outside Dia. of Armor9.0 (0.35) Max Dia. of Armor Ferrule3.2 (0.13)Unthreaded Length \"A\"Case Length \"B\"6.0 (0.235) Max.8Total Length \"C\Miniature MaleCoaxial Connector7.23 (0.285) OutsideDia. Maximum \"D\"
Figure 3 - 3300 5 mm Proximity Probes, Standard Mount3
330171, 1/4-28 UNF-2A, without armor7
330172, 1/4-28 UNF-2A, with armor6
330173, M8X1 thread, without armor7
330174, M8X1 thread, with armor6
BNC Part Number 172036 Revision NC, May 2005
Page 11 of 13
元器件交易网www.cecb2b.com
Figure 4 - Installed Connector Protectors
75 ohm cable3.7 (0.15) max. O.D.RMiniature Male3.9 (0.16) Max. Dia. for FluidLoc cableCoaxial Connector7.6 (0.30) Max. O.D. of ArmorFEP or PFA9.0 (0.35) Max Dia. of Armor FerruleCoated Armor683.87.2 (0.285)83.87.2 (0.285)Armor Length:Max. Dia.(3.30)(3.30)Max. Dia.300 (11.8)less than cable length83.883.8(3.30)(3.30)FEP or PFA InsulatedTriaxial CableStainless Steel FerrulesMiniature FemaleCoaxial Connector8.4 (0.33) Dia.Cable Length +20%, -0%
Figure 5 - 3300 XL Extension Cable
330130, 3300 XL Extension Cable (FEP armor and insulation)
BNC Part Number 172036 Revision NC, May 2005
Page 12 of 13
元器件交易网www.cecb2b.com
Notes:
1. All dimensions are in millimetres (inches) unless otherwise noted.
3. Standard mount 5 mm probes supplied with 13 mm or 7/16-in lock nut.
5. Letters inside quotation marks refer to probe ordering options.
6. Stainless steel armor is supplied with FEP outer jacket for standard probes, PFA outer jacket for ETR probes.
7. FEP jacket is standard non-armored portion of the cable for standard probes, PFA jacket on non-armored portion for ETR probes. 8. Probes ordered with 5 or 9 metre integral cables have a length tolerance of +20%, -0%. 9. Five metre probes are designed for use with the five metre Proximitor® Sensor only.
BNC Part Number 172036 Revision NC, May 2005
Page 13 of 13
因篇幅问题不能全部显示,请点此查看更多更全内容